1. Preparation
a. Connect PS/PSI via USB interface, wait for driver to install. Make sure, only one PS/PSI 8000 is connected to the PC.
b. Make shortcut on DC output. Cable cross section must be sufficient for the max. current of your device!
c. Switch on device
d. Start PS8000_offset_tool.exe
2. Tool
a. Click button 1. Wait for the device to be found and correctly displayed in the 6 fields.
b. Click button 2.
c. Click button 3. A field “Offset in Ampere” will appear:
i. The device will set 0 A. If there is a positive current offset it will be shown, like in the screenshot above.
ii. Field “I monitor” will show a value, most likely negative.
iii. Adjust that value downwards, i. e. increase it by steps of 1 or 10 with the small arrows or enter it directly with the keyboard. Continue increasing “I monitor” until “Offset in Ampere” reaches 0. Best is to have the offset be a little over 0, for example 0,001…0,003 (models with 2 decimal places for current on display) resp. 0,01…0,03 (models with 1 decimal place for current on display)
d. Click button 4.
e. Click button 5.
i. The device will set max. current now! Another field “Offset in Ampere” will appear (beneath button 6), showing the offset (negative or positive) at max. current.
ii. Repeat the same procedure as in step 2-c-iii. with the “I select” field next to button 6. Rules:
1. If offset is negative, make value in “I select” positive.
2. If offset is positive, make value in “I select” negative.
iii. Adjust the value in “I select” until “Offset in Ampere” shows almost zero. It is recommended to keep a small positive offset.
f. Click button 6.
g. Click button 7.
elektro-automatik電源EA-PS8080歸零;德國elektro-automatik電源EA-PS 8080-40 2U/EA-PSI 8160-60 2U偏置補償工具指令
1。準備
A.將PS / PSI通過USB接口,等待驅動程序安裝。確保只有一個PS / PSI 8000連接到PC。
B.在直流輸出上做快捷方式。電纜橫截面必須足以滿足您設備的zui大電流.!
C 開啟電源
D.安裝ps8000_offset_tool.exe
2。工具
點擊按鈕1。等待在6個字段中找到并正確顯示的設備。
點擊按鈕2。
點擊按鈕3。一個字段“抵消安培”將出現:
一,設備將設置0答:如果有一個積極的電流偏移將顯示,如在上面的截圖。
II。現場“我顯示器”將顯示價值,zui有可能的負面。
三、向下調整該值,即用小箭頭加1或10步,或用鍵盤直接輸入。繼續增加“我監測”,直到“抵消安培”達到0。是有偏移是0多一點,例如0001…0003(小數點后2位為當前顯示模式)或。0.01 0.03(與…當前顯示1位小數的模型)
D.點擊按鈕4。
點擊按鈕5。
設備將設置zui大電流現在!另一個字段“抵消安培”將出現(下面按鈕6),顯示偏移量(負或正)在zui大電流。
II。重復同樣的程序,如步驟2-c-iii.與“我選擇”字段旁邊的按鈕6。規則:
1。如果偏移量為負值,則在“我選擇”正。
2。如果偏移為正,使“i選擇”負值為負值。
調整“我選擇”的值,直到“抵消安培”顯示幾乎為零。建議保持一個小的正偏移。
點擊按鈕6。
點擊按鈕7。